For business · Power and IoT

When the power cuts, your network should not notice.

UPS sized on your real load and runtime, protection for racks and switches, and IoT sensors.

Rack UPS cabinet in an equipment room
Fig. 06.0Rack UPS in an equipment roomReference image

01What we do

Clean power from the panel to the device.

  • 01

    UPS sizing and installation

    Sized on watts, with headroom.

    More

    Line-interactive and online double-conversion UPS units, rack and tower, from APC Schneider. Sized on measured or listed load, with headroom and the runtime you need.

  • 02

    External battery packs

    Longer runtime where you need it.

    More

    Extra battery capacity where you need longer runtime, with a plan to replace batteries before they fade.

  • 03

    Power distribution and protection

    PDUs, surge protection, earthing.

    More

    Rack PDUs, surge protection and correct earthing in the cabinet, so one faulty device does not trip a whole rack.

  • 04

    Graceful shutdown

    Servers shut down in order on battery.

    More

    Servers, NAS and virtualization hosts told by the UPS to shut down in order before the batteries run out.

  • 05

    Smart building and IoT sensors

    Sensors for rooms, cabinets and buildings.

    More

    Sensors for server rooms, cabinets and buildings, planned with you during the site survey.

0 ms

An online UPS moves to battery with no gap at all. Your switches and recorders never notice the power cut.

02The details

Open what you need.

01Common problems4
  1. The UPS that lasted two minutes The label says 3 kVA. The batteries are five years old and the load has doubled since it was installed. In the first long cut it gives up before the generator starts.
  2. Switches that restart on every flicker The server is on a UPS. The switches in the floor cabinets are not. A half-second dip restarts them, and every camera and phone with them.
  3. Equipment damaged when the power returns Spikes and unstable voltage after a cut, or when the generator takes over, shorten the life of power supplies. They fail months later and nobody connects it to the cut.
  4. A server room that overheats in silence The air conditioning stops with the power. The UPS keeps the servers running, and the room keeps getting hotter. Nobody knows until something shuts down.
02How we design it4
  1. Watts, not just VA A UPS has two ratings. The watt rating is the one that has to cover your load. We size on watts and keep the unit below about 80% of it.
  2. Runtime for your situation Long enough for the generator to start and stabilise, or long enough for a clean shutdown, or long enough to ride out a scheduled cut. Each is a different battery size.
  3. Battery age is part of the design Sealed lead-acid batteries lose capacity with age and heat. A design that only works with new batteries does not work for long.
  4. Online UPS where the generator is involved Generators can produce unstable voltage and frequency. An online double-conversion UPS isolates sensitive equipment from it.
03Under an SLA contract1
  1. UPS status, load and battery health monitored 24/7 on Business and Mission-Critical plans.

See SLA contracts

Brands we install and support

  • APC Schneider

Rack power distribution from the same server partners: Dell, HP, Lenovo, Huawei.

All partners and brands

Next step

How long did your UPS last in the last power cut?

If you do not know, that is the first thing we would check.